Fire Resistance

Standard Testing

Authority

Test Result

BS 476 part 4, BS EN ISO 1182

Warrington Fire Research

Non combustible

BS 476
part 7

Warrington Fire Research

Class 1 surface spread of flame

BS 476
part 22

CERAM U.K.

180 mins integrity (single side 12mm board)

BS 476
part 22

CERAM U.K.

120 mins integrity & insulation (steel stud)

BS 476 part 22

CERAM U.K.

120 mins integrity & insulation (timber stud)

BS EN ISO 1716

BRE U.K.

Evolved heat of component parts

BS EN ISO 1182

BRE U.K.

Non combustible Class 'A1'

Mechanical & Physical Properties

Test Item

Unit

Test Result

Density (Average)

Kg/m3

1100 ± 100

Bending Strength

N/mm2

>= 12.1

Tensile Strength

N/mm2

>= 1.97

Impact Strength

N/mm2

23

Moisture Content

%

9 ± 5

Moisture Exposure Expansion Rate

%

<= 0.2

Thermal Conductivity

W/mK

0.139

Surface Alkalinity

pH

Between
9.5 ~ 10

Asbestos Check

N/A

Not Detected

Sample Technical Data
This information is provided for indicative purposes. Detailed technical data applicable to specific board thicknesses, including copies of relevant test reports, can be provided on request.